Product Overview
PP scrubber is a wet waste gas purification device built with a polypropylene (PP) tower body. The selection of this equipment starts from tower material and tower structure, not from a specific pollutant. PP is corrosion-resistant to acid and alkali media, light in weight, and operates stably from -10°C to 120°C. The tower can be vertical or horizontal, with single or multi-layer packing, and the spray medium can be circulating water, alkali, or acid depending on the waste gas.


Key Specifications
|
Item |
Parameter |
|
Tower material |
PP (polypropylene) |
|
Structure |
vertical / horizontal |
|
Applicable temperature |
-10 to 120°C |
|
Tower diameter |
Φ300–Φ3000 mm |
|
Air volume |
300–38000 m³/h |
|
Empty tower gas velocity |
2.4–2.7 m/s |
|
Pressure loss |
390–780 Pa |
|
Packing layer |
single / multi-layer |
|
Spray medium |
circulating water / alkali / acid |
|
Mist eliminator |
PP plastic wire filling |
Selection & Comparison Notes
• Step 1: choose vertical or horizontal tower. Vertical tower uses counter-current gas-liquid contact, occupies less floor space, and handles large air volume. Horizontal tower uses cross-flow contact, is lower in height, and suits height-limited installation positions.
• Step 2: choose tower diameter. Tower diameter is matched to air volume; empty tower gas velocity is designed at 2.4–2.7 m/s to ensure gas-liquid contact time meets absorption requirements.
• Step 3: choose packing layer quantity. Single-layer packing suits low-concentration waste gas; multi-layer packing suits high-concentration or high purification requirements. Each additional packing layer increases pressure loss, requiring a higher-pressure fan.
• Step 4: choose spray medium. Circulating water, alkali, or acid selected according to waste gas acidity/alkalinity.
• PP material is corrosion-resistant to acid and alkali media; equipment weight is light and specific strength is high. Pressure loss controlled at 390–780 Pa, reducing matched fan power and long-term power consumption.
• Circulating water pump power and dosing system can be selected according to liquid-gas ratio and site conditions.
Applications
• Electroplating workshop acid mist purification
• Chemical industry acid-base waste gas treatment
• Electronics industry waste gas absorption
• Metallurgy industry acid mist gas purification
• Machining pickling waste gas treatment
• Hardware surface treatment waste gas purification
Customization & OEM
• Tower diameter and height designed to air volume and installation space
• Tower material: PP, PVC, fiberglass
• Structure: vertical or horizontal
• Packing layer quantity configured to waste gas concentration and purification requirements
• Spray medium selected to waste gas acidity/alkalinity
• Inlet/outlet direction adjusted to site duct layout
• Circulating water pump power and dosing system optional
• Liquid-gas ratio designed to working conditions
• OEM/ODM: customized to waste gas composition, air volume, and installation space; customer brand on nameplate and outer packaging
Ordering & Cooperation
| MOQ | 1 unit |
| Lead time | to be confirmed by configuration; standard configurations typically 15–30 days |
| Payment | T/T 30% deposit, 70% before shipment; L/C at sight accepted for large orders |
| Trade terms | FOB / CIF / EXW |
| Packing | wooden case or pallet for container shipment; large towers shipped in sections |
| Port of loading | Shanghai / Ningbo / Qingdao |
| Warranty | one year against manufacturing defects for non-consumables |
| After-sales | technical support for installation and commissioning; spare parts supply for spray nozzles, packing, and circulating pump |
Quality Control
After tower welding, weld seam sealing is checked, confirming no leakage. Before packing installation, packing specification and filling density are checked. Spray system is tested circuit by circuit for spray uniformity. Circulating water pump test run records current and flow. 100% powered test run before packing, confirming spray and circulation system action. Third-party inspection accepted. The factory has supplied this equipment to electroplating, chemical, and metallurgy workshops, and uses this field data to set packing layer quantity and liquid-gas ratio.
FAQ
Q: How to choose between vertical and horizontal tower?
A: Vertical tower occupies less floor space and suits locations with sufficient height; preferred for large air volume. Horizontal tower is lower in height and suits height-limited installation positions, but occupies more floor space. Select based on site space and air volume.
Q: How many packing layers are suitable?
A: Single-layer packing suits low-concentration waste gas treatment; multi-layer packing suits high-concentration or high purification requirements. Each additional packing layer increases pressure loss, requiring a higher-pressure fan. Specific layer quantity depends on initial waste gas concentration and target emission requirements.
Hot Tags: pp scrubber, China pp scrubber manufacturers, suppliers, factory, industrial uv odor removal unit, Plastic fume purification equipment, Printing VOCs treatment system, Spray room odor removal device, uv photolysis exhaust gas purifier, VOC abatement equipment